Posts by AnnetteC
LEED® Registered Buildings
American Hi-Definition Conversion Van Nuys CA Clear Ski Properties LLC Addition of 600 Evergreen 190 solar modules on the structure’s roof gave this array a capacity of 95 kW. Close coordination with Energy Efficiency Solar resulted in the placement of an array that covered more than 50% of the existing room footprint without any structural…
Read MoreMulti-Family Housing
Silvercrest Residence San Diego CA Flewelling & Moody 10-story housing complex employs reinforced concrete flat plates to minimize inter-story height. Foundation consists of belled caissons in order to distribute the relatively large loads over a small footprint into the soil. TLC New Visions Reseda CA 8,000 square foot HUD-funded residential structure with the unique…
Read MoreSeismic Evaluations
Anaheim Marriott Anaheim CA Parking Structure Evaluation Six-story structure with reinforced concrete frames for lateral load resistance in one direction and reinforced concrete shear walls for resistance in the other direction. Evaluated numerous observable cracks and spalls, but deemed the structure’s integrity had not been compromised. 304 West Elm Street Brea CA ASCE 31-03…
Read MoreHistoric Landmarks
Glendora City Hall Glendora CA City of Glendora City Hall 1922 Three-story, unreinforced masonry provided challenging framework for the design of this $700,000 project, which included the addition of an elevator to facilitate access. Pioneer Hall Brea CA City of Brea Community Clubhouse 1923 The ability of the structure to resist current seismic…
Read MoreSeismic Rehabilitations
Glendora Library Glendora CA Strengthening of a non-ductile concrete column and masonry wall structure with carbon fiber reinforced polymer jackets. 2943 Vineyard Avenue Los Angeles CA Repair of a partially collapsed two-story wood light framed structure. Los Angeles Pro Apartements Los Angeles CA Alpha Property Management Inc Seismic upgrade of a…
Read MoreConstruction Failures
Wilshire Boulevard Beverly Hills CA Philadelphia Insurance Companies A shoring failure during construction led to this multi-million dollar loss. Since the policy was an all risk policy, the insurer needed to know the proximate cause of the failure. By piecing together the information provided to us and creating a finite element model of the shoring…
Read MoreFire Damaged Structures
5th Street / Oxnard Boulevard Oxnard CA Schifrin, Gagnon & Dickey Repair of a damaged one-story unreinforced masonry wall building. Possessed a number of structural elements that were not compliant with current code. A closely coordinated effort, greatly assisted by Schifrin, Gagnon & Dickey, led to remedial recommendations and their implementation, that were agreeable to…
Read MoreSeismic Loading on a Retaining Wall
At JCSE, we continue to receive questions whether the 2007 California Building Code (CBC) requires seismic loads induced by retained soils be accounted for in the design and construction of retaining walls. The short answer is yes. There is little evidence that indicated retaining walls had failed due to seismically induced loads. Thus, the CBC…
Read MoreStructural vs. Professional Engineers
All licensed Structural Engineers (S.E.s) are also licensed Professional Engineers (P.E.s). All Professional Engineers, however, are not licensed Structural Engineers. In fact, only a small fraction of Professional Engineers go on to pass the State requirements that allow Professional Engineers to be licensed Structural Engineers. A practicing engineer is initially required to pass an examination…
Read MoreSeismic Evaluation of Existing Buildings
The American Society of Civil Engineers (ASCE) has developed a national standard entitled the Seismic Evaluation of Existing Buildings (ASCE 31-03). The value this standard provides is that a building need not be evaluated by the more stringent current building standards but rather for structural deficiencies that through the course of time have proven to…
Read More